Posted: 4th February 2020
Michell Bearings has recently completed a re-engineered upgrade to the main generator bearings at a hydro power station in the north west of Scotland.
The engineering team began by modifying the 1950’s thrust and guide bearing’s design to improve its reliability. This included the installation of high pressure jacking for machine start up and improved instrumentation to provide more accurate and remote monitoring.
Further improvements were made to increase the bearing’s efficiency and improve environmental impact by upgrading the bearing’s oil sealing, as well as improving access for regular maintenance.
The overall upgrade will mean that the generator’s availability to the grid will be far higher than before and reliability will be greatly improved.
Find out more about our repair service or contact us if you would like to make an enquiry.
Send us an image of your issue and let our experts diagnose your problem
Michell Bearings
Waldridge Way,
Simonside East Industrial Park,
South Shields,
NE34 9PZ.Tel: +44 (0) 191 273 0291
Email: sales@michellbearings.com
Email: hrteam@britishengines.com
Email: recruitment@britishengines.com© Michell Bearings.
Registered Office Address: 11 Glasshouse Street, St Peter's, Newcastle upon Tyne. NE6 1BS. Company registered in England and Wales no. 9390648
- Thrust Bearings
- Vertical Bearings